1. Adhere to all CREC’s, local code and OSHA’s safety requirements. 2. Remove existing system down existing decking. 3.

🔥 42/100
← All projects
permittingCommercial

1. Adhere to all CREC’s, local code and OSHA’s safety requirements. 2. Remove existing system down existing decking. 3.

SPX-128046

Hartford, Hartford County, Connecticut

Project ID
SPX-128046
Estimated value
$1.1M
Square footage
Not reported
Opened / announced
Mar 30, 2026
Owner
Not reported
General contractor
Not reported
Architect
Not reported
Brands mentioned
None in public seed

Project overview

Hartford commercial permit COM-ALT-26-000101 (Commercial Alteration Permit): 1. Adhere to all CREC’s, local code and OSHA’s safety requirements. 2. Remove existing system down existing decking. 3. Mechanically fasten one base layer of 3.5”, 20PSI polyisocyanurate insulation 4. Using Type III hot asphalt, adhere 1/8” tapered layer of 20 PSI polyisocyanurate while staggering all seams. a. Install 1/4:12” crickets between drains and behind all curbs b. Install drain inserts and sump at a minimum of 6X6’. 5. Using Type III hot asphalt, adhere ½” pre-primed fiber board while staggering all seams. 6. Install any needed wood blocking, PT 2x6 TYP at perimeter, curbs and as needed 7. Install and set 45 D cant strip at all vertical to field transitions in flashing adhesive. 8. Install field base sheet and mineral embedded capsheet with using Type III hot asphalt at 25lbs per sq. for each membrane layer while staggering all seams and laps between ply’s. 9. Install base sheet and mineral capsheet flashings with cold applied flashing adhesive at a rate of 5 Gal/Sq. and properly terminate according to the details provided. (Flashings plys to be no longer than 8ft in length) a. All vertical cap flashing seams shall be three-coursed with aluminized mastic and reinforced with mesh. b. All finished flashings shall be terminated with a typ. termination bar at 8”OC 10. Install new metal slip flashings or surface mounted flashing extender to cover newly installed membrane terminations. 11. Install pre manufactured, flashless edge metal systems along the perimeters exterior, fascia trim extensions as needed, or new gutter and leaders.. 245 LOCUST ST, HARTFORD, CT 06114.

Key specs

  • Commercial Alteration Permit
  • 245 LOCUST ST, HARTFORD, CT 06114
  • Permit COM-ALT-26-000101

Still open for manufacturers

Active commercial building permit. Early product/spec window.

Manufacturer watch list

  • hvac
  • roofing
  • lighting
  • concrete
  • fire suppression

Timeline

  1. Permit issued

    Mar 30, 2026 · Prior research

Priority score

Watch

42/100

Value
28/40
Recency
14/35
News coverage
0/25
📍 Regional location pending

Hartford, Hartford County, CT

Exact coordinates for this project haven't been geocoded yet.