1. Install two complete 14 SEER HVAC systems located in the basement with one to feed the first floor and one system to
🔥 38/1001. Install two complete 14 SEER HVAC systems located in the basement with one to feed the first floor and one system to
SPX-127462
Hartford, Hartford County, Connecticut
- Project ID
- SPX-127462
- Estimated value
- $51,000
- Square footage
- Not reported
- Opened / announced
- Apr 16, 2026
- Owner
- Not reported
- General contractor
- Not reported
- Architect
- Not reported
- Brands mentioned
- None in public seed
Project overview
Hartford commercial permit MISC-MEC-26-000063 (Mechanical Permit): 1. Install two complete 14 SEER HVAC systems located in the basement with one to feed the first floor and one system to feed the second floor. (The attic/3rd floor to have a perimeter duct system). 2. Equipment to be 40,000 BTU two stage furnaces with 2 tons of cooling on 2nd floor and 1.5 ton on first floor. 3. Includes supplies, returns and transfers if needed. System will be built and developed on site and will need supervision on what we’re allowed to do by owner. 4. These systems will have a total of two zones. (Attic can be adjusted to have a motorized damper system with its own T-Stat if ever wanted as long as low voltage wiring is roughed in previously. 5. Install a Mitsubishi 9,000 to 12,000 MBH Hyper-Heat ductless split heat pump for the room that’s on slab. 6. All start-up and testing is included.. 279 FARMINGTON AV, HARTFORD, CT 06105. Hartford commercial permit MISC-MEC-26-000064 (Mechanical Permit): 1. Install two complete 14 SEER HVAC systems located in the basement with one to feed the first floor and one system to feed the second floor. (The attic/3rd floor to have a perimeter duct system).REF: RES-ALT-25-000166 2. Equipment to be 40,000 BTU two stage furnaces with 2 tons of cooling on 2nd floor and 1.5 ton on first floor. 3. Includes supplies, returns and transfers if needed. System will be built and developed on site and will need supervision on what we’re allowed to do by owner. 4. These systems will operate as single zones. (Attic can be adjusted to have a motorized damper system with its own T-Stat if ever wanted as long as low voltage wiring is roughed in previously. 5. All start-up and testing is included.. 285 FARMINGTON AV, HARTFORD, CT 06105.
Key specs
- Mechanical Permit
- 279 FARMINGTON AV, HARTFORD, CT 06105
- Permit MISC-MEC-26-000063
- 285 FARMINGTON AV, HARTFORD, CT 06105
- Permit MISC-MEC-26-000064
Still open for manufacturers
Active commercial building permit. Early product/spec window.
Manufacturer watch list
- hvac
- roofing
- lighting
- concrete
- fire suppression
Timeline
Permit issued
Apr 16, 2026 · Prior research
Priority score
Low signal38/100
- Value
- 22/40
- Recency
- 16/35
- News coverage
- 0/25
Hartford, Hartford County, CT
Exact coordinates for this project haven't been geocoded yet.