9449 Silver Creek Rd

🔥 32/100
← All projects
permittingIndustrial

9449 Silver Creek Rd

SPX-112909

Fort Worth, Tarrant County, Texas

Project ID
SPX-112909
Estimated value
$10.2M
Square footage
1,113,290 SF
Opened / announced
Oct 29, 2024
Owner
FW 820 LLC. MAJESTIC REALTY CO
General contractor
Not reported
Architect
Not reported
Brands mentioned
None in public seed

Project overview

Fort Worth commercial permit PB24-16248: X TEAM /// /remodel of existing warehouse, add dock levelers, restrooms and workstations for distribution of computer rack servers and misc related parts. 9449 SILVER CREEK RD. Fort Worth commercial permit PB24-18565: X TEAM /// Remodel and Expansion of Existing Office. 9449 SILVER CREEK RD. Fort Worth commercial permit PB24-18566: X TEAM /// Temporary office/construction trailers. 9449 SILVER CREEK RD. Fort Worth commercial permit PB25-01790: X TEAM /// Temporary office/construction trailers. 9449 SILVER CREEK RD. Fort Worth commercial permit PB25-02568: Installation of pallet racking into an existing warehouse. Proposed square footage (racking being installed) = 77,532 sq ft.. 9449 SILVER CREEK RD. Fort Worth commercial permit PB25-05939: X TEAM /// Remodel existing occupied warehouse, add dock levelers, restrooms and work stations. 9449 SILVER CREEK RD. Fort Worth commercial permit PB25-09868: X TEAM /// Temporary storage room for Lithium-ion batteries. 9449 SILVER CREEK RD. Fort Worth commercial permit PB25-12573: Installation of pallet racking inside of an existing customer warehouse - no mechanical, electrical, or plumbing work being conducted within this scope of work.. 9449 SILVER CREEK RD. Fort Worth commercial permit PB26-01270: The project is being completed in phases, with this submission representing Phase 1 for the generator installation. This application covers the scope of work for the Generator Design project in Fort Worth, TX, which includes the installation of two new 500kW natural gas generators on concrete equipment pads . Phase 1 (Current Submission): Involves site preparation, utility installation, structural concrete pads, and electrical tie-ins for the generators. The work includes installation of approximately 1125 LF of 3-inch natural gas piping and the construction of reinforced concrete pads . Electrical work centers around installing a 4000A Automatic Transfer Switch (ATS) and associated conduit/wiring, requiring adherence to NEMA 3R and 4X standards for outdoor equipment. Phase 2 (Separate Submission): A future project for site security improvements is anticipated but is shown for reference only in these plans (pp. 1, 3). This separate submission is necessary because the second phase involves disturbing an impervious area which impacts stormwater management and will be submitted to the City of Fort Worth under a separate permit application.. 9449 SILVER CREEK RD. Fort Worth commercial permit PB26-01386: This fencing permit application is for the Google DFW1.0 Logistics Facility Generator & Site Security project in Fort Worth, TX, where two high-security perimeter fence systems are proposed to enhance site access control and protection. The scope includes installation of approximately 1,370 linear feet of 8-foot-tall Ameristar Impasse II Trident fencing at the site entry and visitor parking areas (Layer 1), and approximately 4,820 linear feet of 8-foot-tall Ameristar Impasse II Anti-Scale Gauntlet fencing around the truck yard and secure access lanes (Layer 2), as shown in the attached site layout. All fencing will be constructed in accordance with Ameristar manufacturer specifications and standards (see attached), and will meet all applicable City of Fort Worth requirements for high-security perimeter fencing.. 9449 SILVER CREEK RD. Fort Worth commercial permit CG26-00053: Grading permit application for Phase 1 of the Google DFW1.0 Logistics Facility Generator & Site Security project at 9449 Silver Creek Rd (Majestic Silver Creek Addition, Block 1, Lot 2). Work includes installation of two 500 kW natural gas generators on a new 18’ x 52’ reinforced concrete equipment pad, associated utility trenching, approximately 1,125 linear feet of 3-inch natural gas piping, and related erosion and stormwater control measures. Additionally, grading and site work support installation of approximately 6,190 linear feet of 8-foot-tall Ameristar high-security fencing around site entry, visitor parking, and truck yard areas as part of perimeter security improvements. Drainage study DS-21-0139 has been accepted. All work complies with City of Fort Worth stormwater, zoning, and grading requirements.. 9449 SILVER CREEK RD. Fort Worth commercial permit CG26-00108: The proposed project at 9449 Silver Creek Road, Fort Worth, TX 76108 encompasses site grading and preparation over approximately 2.56 acres to support a series of security and infrastructure upgrades. Scope includes removal of existing pavement, sidewalks, curbs, and selective landscaping to accommodate installation of new security fencing, access gates, and electrical infrastructure for generator and EV charging stations. Earthwork operations will establish final grades to improve site drainage and facilitate construction of new utility lines, including water, sanitary sewer, and electrical conduits. Erosion and sediment control measures such as silt fencing and inlet protection will be implemented and maintained throughout construction in accordance with City of Fort Worth and TCEQ standards to prevent sediment runoff. Upon completion, all disturbed areas will be restored with appropriate surface treatments. The improvements are designed to enhance security, upgrade onsite utilities, and ensure compliance with local and state stormwater management requirements.. 9449 SILVER CREEK RD. Fort Worth commercial permit PB26-08790: Installation of pallet racking inside of an existing customer warehouse - no MEP. Specialty fire suppression scheme (in-rack sprinklers) being handled by sprinkler contractor separately.. 9449 SILVER CREEK RD. Fort Worth commercial permit PB26-09263: X TEAM /// This project consists of interior improvements includes addition of a new battery room and modification to office areas. Work includes selective demolition; construction of new interior partitions, finishes; and associated architectural improvements. The project also includes mechanical, electrical, plumbing, fire alarm, and fire protection modifications required to support the new layout, including relocation and adjustment of existing ductwork, diffusers, piping, sprinklers, devices, and related accessories. All work will be field verified and coordinated with all disciplines and performed in compliance with applicable codes and regulations. The project is an interior renovation only and does not increase building area or height and does not change the existing occupancy or occupant load.. 9449 SILVER CREEK RD. Fort Worth commercial permit PB26-09264: X TEAM /// The scope of work is a s follows: Install a new entrance vestibule and install additional turnstiles and a metal detector at the entrance and 2 trucker cages inside the middle of warehouse. Add new lockers at existing locker area. Install two driver access cages inside the warehouse. Scope Also Includes associated electrical, conduit, patching, and finish work.. 9449 SILVER CREEK RD.

Key specs

  • Remodel
  • 9449 SILVER CREEK RD
  • Permit PB24-16248
  • Permit PB24-18565
  • Addition
  • Permit PB24-18566
  • New
  • Permit PB25-01790
  • Permit PB25-02568
  • Permit PB25-05939
  • Permit PB25-09868
  • Permit PB25-12573
  • Permit PB26-01270
  • Permit PB26-01386
  • NA
  • Permit CG26-00053
  • Permit CG26-00108
  • Permit PB26-08790
  • Permit PB26-09263
  • Permit PB26-09264

Still open for manufacturers

Active commercial building permit. Early product/spec window.

Manufacturer watch list

  • roofing
  • hvac
  • dock equipment
  • concrete
  • lighting
  • fire suppression
  • glazing
  • elevators
  • flooring
  • doors and hardware

Timeline

  1. Permit issued

    Oct 29, 2024 · Prior research

Priority score

Low signal

32/100

Value
32/40
Recency
0/35
News coverage
0/25